background image
TCH.1C-27J-2-27JG
Consumable Material Required:
None
Safety Conditions:
Be aware of information contained in Paragraph (refer to
para 
2-1
) SAFETY PRECAUTIONS before performing
maintenance.
PROCEDURE:
2-40.1
ELEVATORS FREE DEFLECTION CHECK (refer
to figure 
2-34, sheet 1/3
)
1.Ensure that left elevator is installed but not connected
to the control line.
2.Install the templates (AGE NO. 00065) for elevator
travel check on the left elevator trailing edge.
3.Put the double side adhesive tape on the top surface
of the elevator, non in contact with its rivets, and
position on it the digital inclinometer (AGE NO.
00061), parallel to the template.
4.With the elevators in neutral position reset the
inclinometer, then remove the template.
5.Starting from left elevator to neutral position, move by
hand the left surface fully upward and fully downward
and check that the travel is 27.5
°
 
+
0.5
°
 / -0
°
 in both
conditions, without interferences.
(Cont'd)
27-30-00
2-318