TCH.1C-27J-2-27JG
2-40.1
ELEVATORS FREE DEFLECTION CHECK (refer
to figure
(Cont'd)
NOTE
If the above travel values are not reached,
adjust properly the end stop screws (located
on the stabilizer) in order to satisfy the
requirements. If necessary, perform the wire
locking of the end stop screw.
6.Ensure that right elevator is installed but not
connected to the control line.
7.Install the templates (AGE NO. 00065) for elevator
travel check on the right elevator trailing edge.
8.Put the double side adhesive tape on the top surface
of the elevator, non in contact with its rivets, and
position on it the digital inclinometer (AGE NO.
00061), parallel to the template.
9.With the elevators in neutral position reset the
inclinometer, then remove the template.
10.Starting from right elevator to neutral position, move
by hand the right surface fully upward and fully
downward and check that the travel is 27.5
°
+
0.5
°
/
-0
°
in both conditions, without interferences.
(Cont'd)
27-30-00
2-319