background image
TCH.1C-27J-2-27JG
2-43.2
INSTALLATION. Proceed as follows:
(Cont'd)
CAUTION
––––––––––––––––––––––––––––––––––
Do not perform the complete tension of
the cable.
––––––––––––––––––––––––––––––––––
FOLLOW ON MAINTENANCE:
1.Perform Elevator Cable Tension.
2.Perform the functional test:
A.MANOUVRE EFFORT AND Q-FEEL
FUNCTIONAL CHECK (refer to para 
2-53
) .
B.CHECK OF RETURN TO NEUTRAL POSITION
(refer to para 
2-44
).
C.ADJUSTMENT OF NEUTRAL POSITION (refer to
para 
2-44
) .
D.ELEVATOR CONTROL SYSTEM (refer to para
2-41
), (refer to para 
2-44
) and (refer to para 
2-47
).
3.Close thermal insulation screen.
4.Install Pilot (Copilot) seat (refer to manual
TCH.1C-27J-2-25JG
).
5.Close the access panels:
A.212AZ (212EZ).
B.212BZ (212DZ).
C.214BZ (213BZ).
D.213AZ.
E.130AH (130AE).
F.130AD (130AG).
6.Disconnect external electrical power (refer to manual
TCH.1C-27J-2-00GV
) .
7.Disconnect external hydraulic power (refer to manual
TCH.1C-27J-2-00GV
) .
27-30-05
2-354