TCH.1C-27J-2-27JG
AGE Required:
None
Consumable Material Required:
LCM
No.
NOMENCLATURE
P/N
QTY
00031
PACKING,
PREFORMED
M83461/2-904
2,00
00032
O-RING,
PREFORMED
M83461/2-906
2,00
00043
HYDRAULIC FLUID
MIL-PRF-83282D
AR
00052
PIN, COTTER
MS24665-153
5,00
Safety Conditions:
maintenance.
PROCEDURE:
2-50.1
REMOVAL. Remove elevator actuator as follows:
WARNING
––––––––––––––––––––––––––––––––––
TOPS MUST BE FIXED ON PIPES AFTER
REMOVAL.OPEN ALL THE NITROGEN
CHARGING VALVE VERY SLOWLY TO
PREVENT NITROGEN VAPOR FROM
COMING IN TOUCH WITH THE EYES.DO
NOT BREATHE THE NITROGEN VAPOR
COMING OUT FROMTHE NITROGEN
CHARGING VALVE, IT COULD BE MIXED
WITH HYDRAULIC FLUID.
––––––––––––––––––––––––––––––––––
(Cont'd)
27-30-25
2-419