TCH.1C-27J-2-27JG
2-50.1
REMOVAL. Remove elevator actuator as follows:
(Cont'd)
NOTE
Install the protection cap on the pipes and
the electrical connectors that you
disconnect.
A.Disconnect the two electrical connectors from LH
(RH) actuator 11CGA (6CGA) and 11CGB(6CGB).
B.Disconnect the jumper from actuator as follow:
remove the cotter pin, unscrew the nut, remove the
washers and the bolt.
C.Use a container to collect the drained fluid.
Unscrew the nuts and disconnect the four flexible
pipesfrom the actuator: inlet and outlet of system
No 1 inlet and outlet of the system No 2.
D.Close the four flexible pipe by caps.
E.Close the four connections on the actuator by
caps.
F.Disconnect the input lever from actuator as follow:
remove the cotter pin, unscrew the nut remove
washers the bolt and the bushing.
G.Disconnect the centering spring lever from the
actuator as follow:
1.remove the cotter pin,
2.unscrew the nut,
(Cont'd)
27-30-25
2-420