TCH.1C-27J-2-27JG
2-52
ELEVATOR EMERGENCY TRIM ACTUATOR -
REMOVAL AND INSTALLATION
INPUT CONDITION:
Aircraft Applicability:
04162, 04180
Required Conditions:
1.Isolate hydraulic power (refer to manual
2.Disable Cargo Ramp Function.
3.Lock the elevators by gust lock.
4.Open thermal insulation screen.
Recomended Personnel:
NONE
Periodicity: AR - AS REQUIRED
Total Maintenance Time: 130 (Min.)
Total Time Detention System:
85 (Min.)
AGE Required:
AGE
No.
NOMENCLATURE
P/N
00181
Kit, flight controls rigging
pins
11G001-C052200-801
Consumable Material Required:
None
Safety Conditions:
maintenance.
27-30-35
2-432