TCH.1C-27J-2-27JG
Consumable Material Required:
None
Safety Conditions:
maintenance.
PROCEDURE:
NOTE
This procedure is valid for LH Q-FEEL
Actuator. For RH Q-Feel Actuator is similar.
2-55.1
)
CAUTION
––––––––––––––––––––––––––––––––––
Install protection caps on the
disconnected electrical connectors.
––––––––––––––––––––––––––––––––––
1.Disconnect electrical connector (7CGA) (1) from the
Q-FEEL Actuator (7CG) (4).
2.Disconnect the bonding lead (7) by removing screw
(5) and washer (6).
3.Hold the Q-FEEL Actuator (7CG) (4) and remove bolts
(2), washers (3 and 8) castellated nuts (9) and cotter
pins (10). Discard removed cotter pins.
4.Remove Q-FEEL Actuator (7CG) (4).
2-55.2
)
1.Install Q-FEEL Actuator (7CG) (4).
2.Hold the LH Q-FEEL Actuator (7CG) (4), install it on
its seat, insert the bolts (2), washers (3 and 8) and
castellated nuts (9), then torque tighten to 90 - 100 in
lb (AGE NO. 00054).
3.Insert new cotter pins (10) on the Q-FEEL Actuator
connection.
(Cont'd)
27-30-40
2-463