background image
TCH.1C-27J-2-27JG
2-63.2
INSTALLATION. Install elevator accumulator as
follows:
(Cont'd)
NOTE
Lubricate all packings and O-ring with
hydraulic fluid.
A.Position the clamps on the accumulator.
B.Position the accumulator on its support.
C.Hold the accumulator, then tight and lock the
clamps fixing the accumulator.
D.Place new O-rings on the inlet and outlet pipe and
connect it on the accumulator torque tighten the
nut on top of inlet and outlet pipe.
E.Place new O-rings on the nitrogen pipe and
connect it on the accumulator torque tighten the
nut on top of nitrogen pipe.
F.Connect the electrical cable.
G.Remove from the aircraft the container with
drained fluid.
CAUTION
––––––––––––––––––––––––––––––––––
Dont use the drained fluid collected to
refill hydraulic circuit.It is contamined,
discard it.
––––––––––––––––––––––––––––––––––
(Cont'd)
27-30-70
2-504