TCH.1C-27J-2-27JG
Consumable Material Required:
LCM
No.
NOMENCLATURE
P/N
QTY
00011
NUT, SELF-LOCKING H14-3
3,00
00433
AEROSHELL 17
MIL-G-21164D
AR
00434
AEROSHELL
33MS077009
MIL-G-21164D
AR
Safety Conditions:
maintenance.
PROCEDURE:
NOTE
The LH flap position transducer is shown in
the following subtask. The procedure for RH
flap position transducer is similar.
2-73.1
)
CAUTION
––––––––––––––––––––––––––––––––––
Install protection caps on the
disconnected electrical connectors.
––––––––––––––––––––––––––––––––––
1.Disconnect the electrical connectors (7CAA and
7CAB) (4 and 5) from the flap position transducer
(7CA) (6).
2.Position a container (AGE NO. 00074) in order to
collect drained hydraulic fluid.
3.Remove bolts (3, 14 and 15), flat washers (7, 10 and
12), self locking nuts (8, 9 and 11) that connect the
flap position transducer (7CA) (6) to its support
(13).Discard removed self locking nuts.
(Cont'd)
27-50-40
2-588