TCH.1C-27J-2-27JG
2-74.1
REMOVAL. Proceed as follows:
(Cont'd)
G.Extract and remove the flap slidingend assy from
flap cable assy.
H.Remove the wire locking that fix the flap swivelend
nut and the casing nut on the bottom of the flap
swivelend assy.
I.Unscrew the flap casing assy, unscrew the two
nuts that fix the flap swivelend assy on the
structure.
J.Remove the flap swivelend assy from the flap
cable assy.
2-74.2
INSTALLATION. Proceed as follows:
A.Install the Flap Swivelend Assy.
B.Insert the Flap Swivelend Assy from Flap Cable
Assy.
C.Position the flap swivelend assy on the structure.
D.Screw the two nuts that fix the flap swivelend assy
on the structure and torque tighten to 106
÷
115 in
lb.
E.Screw the casing assy into the flap swivelend assy
and torque tighten to 44
÷
53 in lb.
F.Lock nuts with safety wire, using double twist
method, per MS33540.
(Cont'd)
27-50-45
2-594