background image
TCH.1C-27J-2-27JG
Be aware of information contained in SAFETY
PRECAUTIONS (refer to para 
1-2
) before performing
maintenance.
PROCEDURE:
2-77.1
REMOVAL (refer to figure 
2-71
)
1.Open FCS 1 Control Panel (103VE) (1) by loosening
six dzus (2).
2.Remove the FLAP Lever Knob (3) by loosening the
screw that fix it to lever (5).
3.Loosen the four screws (4) that fix the Flap Lever (5)
to FCS 1 Control Panel (103VE) (1).
CAUTION
––––––––––––––––––––––––––––––––––
Install protection caps on the
disconnected electrical connectors.
––––––––––––––––––––––––––––––––––
4.Lift the FCS 1 Control Panel (103VE) (1) and
disconnect the electric connectors (103VEA and
103VEB) (6 and 7).
5.Remove FCS 1 Control Panel (103VE) (1).
2-77.2
INSTALLATION (refer to figure 
2-71
)
NOTE
Remove protection caps from the electrical
connectors to be installed.
1.Connect the electric connectors (103VEA and
103VEB) (6 and 7) on the FCS 1 Control Panel
(103VE) (1).
2.Place the FCS 1 Control Panel (103VE) (1) and
tighten the screws (4) that fix it to flap lever (5).
3.Install the lever knob (3) using the screw that fix it to
lever (5).
4.Install the FCS 1 Control Panel (103VE) (1) by
tightening six dzus (2).
27-50-60
2-612