background image
TCH.1C-27J-2-27JG
2-90
LH (RH) LIFT DUMPER ACTUATOR -
REMOVAL AND INSTALLATION
INPUT CONDITION:
Aircraft Applicability:
04162, 04180
Required Conditions:
1.Set flap position down.
2.Disconnect electrical power from aircraft (refer to
manual 
TCH.1C-27J-2-00GV
).
3.Isolate hydraulic power (refer to manual
TCH.1C-27J-2-00GV
).
4.Position maintenance platform (AGE NO. 00074)
5.Open the access panel 532C (632C).
Recomended Personnel:
PROCEDURE
MECH.
CODE
QTY
TOTAL TIME
(MIN.)
WORK
ZONE
Input Condition
AFM
1
15,00
Removal
AFM
1
30,00
Installation
AFM
1
35,00
Follow
Maintenance
AFM
1
15,00
Periodicity: AR - AS REQUIRED
Total Maintenance Time: 95 (Min.)
Total Time Detention System:
95 (Min.)
AGE Required:
AGE
No.
NOMENCLATURE
P/N
00054
Kit, torque wrenches
G0001200001-001**
27-60-20
2-688