TCH.1C-27J-2-27JG
Consumable Material Required:
None
Safety Conditions:
maintenance.
PROCEDURE:
2-91.1
REMOVAL. Remove control valve as follows:
A.Position the container in order to collect drained
fluid.
B.Disconnect electric connector.
C.Unscrew the nut and disconnect supply hydraulic
pipe.
D.Close the pipe with a plug.
E.Unscrew the nut and disconnect return hydraulic
pipe.
F.Close the pipe with a plug.
G.Unscrew the nut and disconnect inlet pipe to
actuator.
H.Close the pipe with a plug.
I.Unscrew 4 bolts and remove 4 flat washers that fix
lift dumper actuator with structure.
J.Remove the lift dumper control valve.
27-60-25
2-696