background image
TCH.1C-27J-2-29JG
2-7.3
FLUSHING NO. 1 SYSTEM (refer to figure 
2-5,
sheet 2/2
) and (refer to figure 
2-5, sheet 1/2
)
(Cont'd)
10.Cycle rudder, ailerons and elevator through their full
deflection by moving rudder pedals and control wheel
for 15 minutes. Actuate wheel brakes
(parking/emergency) for 15 minutes. Use caution to
prevent damage to components.
11.Actuate flaps through 10 complete cycles.
12.With hydraulic test stand (AGE NO. 00262) regulated
as per above step 6, drain the reservoir by opening
the reservoir drain cock (6). After emptying reservoir,
refill it again.
13.Take an hydraulic fluid sample from the system in
accordance with (refer to para ).
NOTE
If the hydraulic fluid sample exceeds the
maximum contamination limit, restart the
procedure from step 8. before replacing the
filter elements.
14.Disconnect the pressure hose and suction hose from
hydraulic test stand (AGE NO.00262) to No. 1 system
pressure ground sockets (1 and 2).
15.Remove all the filter elements of No.2 system and
replace them with a new one, (refer to para 
2-12
) ,
(refer to para 
2-9
) and (refer to para 
2-11
) .
NOTE
Once the flushing procedure is completed,
make sure that the "Dummy" filter has been
removed.
29-10-00
2-45