TCH.1C-27J-2-29JG
2-8.2
) and
(refer to figure
)
WARNING
––––––––––––––––––––––––––––––––––
TWO PEOPLE ARE NEEDED FOR THE
RESERVOIR INSTALLATION TO
PREVENT INJURY.
––––––––––––––––––––––––––––––––––
WARNING
––––––––––––––––––––––––––––––––––
HYDRAULIC FLUID IS ACID. AVOID
CONCTACT WITH SKIN AND WEAR
APPROPRIATE, IMPERVIOUS CLOTHING
WHEN HANDLING THE HYDRAULIC
FLUIDS. IF YOU DO NOT OBEY THESE
SAFETY PRECAUTIONS, SEVERE
INJURY MAY OCCUR.
––––––––––––––––––––––––––––––––––
NOTE
Remove protection caps from the electrical
connectors and hoses to be installed.
1.Dress reservoir (2) by installing new O-rings (5, 14,
38, 30, 34 and 43) (LCM NO. 00027, 00031 and
00032) and tighten draining union (43) torque to 155
inlb thru 165 inlb (1.8 mkg thru 1.9 mkg) (AGE NO.
00054), tighten case drain EDP union (34) torque to
155 inlb thru 165 inlb (1.8 mkg thru 1.9 mkg) (AGE
NO. 00054), tighten case drain ACMP union (38)
torque to 95 inlb thru 105 inlb (1.1 mkg thru 1.2 mkg)
(AGE NO. 00054), tighten return union (14) torque to
280 inlb thru 305 inlb (3.2 mkg thru 3.5 mkg) (AGE
NO. 00054), tighten union (30) torque to 800 inlb thru
900 inlb (9.2 mkg thru 10 mkg) (AGE NO. 00054) and
tighten pressurization union (5) torque to 95 inlb thru
105 inlb (1.1 mkg thru 1.2 mkg) (AGE NO. 00054).
(Cont'd)
29-10-05
2-54