background image
TCH.1C-27J-2-29JG
2-11.1
REMOVAL (refer to figure 
2-9
) (Cont'd)
WARNING
––––––––––––––––––––––––––––––––––
HYDRAULIC FLUID IS ACID. AVOID
CONCTACT WITH SKIN AND WEAR
APPROPRIATE, IMPERVIOUS CLOTHING
WHEN HANDLING THE HYDRAULIC
FLUIDS. IF YOU DO NOT OBEY THESE
SAFETY PRECAUTIONS, SEVERE
INJURY MAY OCCUR.
––––––––––––––––––––––––––––––––––
CAUTION
––––––––––––––––––––––––––––––––––
Do not use drained fluid from Hydraulic
System. A hydraulic fluid leak may occur.
This would cause damage to the
equipment and loss of mission
effectiveness.
––––––––––––––––––––––––––––––––––
1.Cut lock wire (1).
2.Loosen filter bowl (2).
3.Remove filter element.
2-11.2
INSTALLATION (refer to figure 
2-9
)
1.Install new filter element into filter bowl (2).
2.Fill filter bowl (2) with clean hydraulic fluid (LCM NO.
00043).
3.Torque tighten the filter bowl (2) to 354 in bl thru 443
in bl (4.1 m kg thru 5.1 m kg) (AGE NO. 00054).
4.Install lock wire (1).
29-10-05
2-73