background image
TCH.1C-27J-2-29JG
CAUTION
––––––––––––––––––––––––––––––––––
Do not use drained fluid from Hydraulic
System. A hydraulic fluid leak may occur.
This would cause damage to the
equipment and loss of mission
effectiveness.
––––––––––––––––––––––––––––––––––
NOTE
This procedure is valid for left high pressure
filter. For right high pressure filter is similar.
2-12.1
REMOVAL (refer to figure 
2-10, sheet 1/2
) and
(refer to figure 
2-10, sheet 2/2
)
CAUTION
––––––––––––––––––––––––––––––––––
Install protection caps on the
disconnected hoses.
––––––––––––––––––––––––––––––––––
1.Use a container to collect drained fluid.
2.Loosen the nut and disconnect the inlet hydraulic pipe
(4).
3.Loosen the nut and disconnect the outlet hydraulic
pipe (8).
4.Remove the three bolts (1), flat washers (2 and 6) and
self locking nuts (5). Discard removed self locking nut.
5.Remove the filter (3).
2-12.2
INSTALLATION (refer to figure 
2-10, sheet 1/2
)
and (refer to figure 
2-10, sheet 2/2
)
NOTE
Remove protection caps from the hoses to
be installed.
1.Loosen the filter bowl (7).
2.Check presence of filter element.
(Cont'd)
29-10-10
2-78