TCH.1C-27J-2-29JG
Consumable Material Required:
LCM
No.
NOMENCLATURE
P/N
QTY
00016
LOCK WIRE
MS20995C32
AR
00026
RETAINER,
PACKING
MS28773-08
1,00
00027
PACKING,
PREFORMED
M83461/2-908
2,00
00028
TUBE PLUG
MS21913-6
1,00
00029
CUPS
MS21914-6J
2,00
Safety Conditions:
maintenance.
PROCEDURE:
WARNING
––––––––––––––––––––––––––––––––––
BEFORE YOU REMOVE ANY HYDRAULIC
COMPONENT, RELEASE SYSTEM
0PRESSURE, IN ORDER TO PREVENT
INJURIES TO PERSONNEL AND
DAMAGE TO THE EQUIPMENT.
––––––––––––––––––––––––––––––––––
WARNING
––––––––––––––––––––––––––––––––––
HYDRAULIC FLUID IS ACID. AVOID
CONCTACT WITH SKIN AND WEAR
APPROPRIATE, IMPERVIOUS CLOTHING
WHEN HANDLING THE HYDRAULIC
FLUIDS. IF YOU DO NOT OBEY THESE
SAFETY PRECAUTIONS, SEVERE
INJURY MAY OCCUR.
––––––––––––––––––––––––––––––––––
29-10-10
2-84