background image
TCH.1C-27J-2-29JG
2-13.1
REMOVAL (refer to figure 
2-11
) (Cont'd)
9.Remove from high pressure filter (9) the union (7) and
the performed packing (6). Discard removed
performed packing.
10.Remove the outlet side TEE reducer (2) from high
pressure filter (9) and remove retainer packing (4) and
performed packings (5). Discard removed retainer and
performed packings.
2-13.2
INSTALLATION (refer to figure 
2-11
)
NOTE
Remove protection caps from the electrical
connectors and hoses to be installed.
1.Connect at the high pressure filter (9) the new
performed packing (6) (LCM NO. 00027) and the
union (7). Torque tighten (AGE NO. 00054) to 3,2 mkg
thru 3,5 mkg (280 in lb thru 305 in lb).
2.Install a new retainer packing (4) and new performed
packings (5) (LCM NO. 00027) and connect outlet
side TEE reducer (2) at the high pressure filter (9).
Torque tighten nut (AGE NO. 00054) to 280 in lb thru
305 in lb (3.2 mKg thru 3.5 mKg).
3.Position the high pressure filter (9) and insert the inlet
pipe (8) in the filter inlet port.
4.Install at the high pressure filter (9), bolts (10) and
washers (11). Torque tighten (AGE NO. 00054) to 80
thru 88 in lb (0.9 mKg thru 1.0 mKg).Install the three
bolts and washers and tighten to 0,9 mkg thru 1,0 mkg
(80 thru 88 in lb).
5.Install the Low Pressure Switch outlet pipe (1) and
torque tighten the TEE reducer nut (3) to 3,2 mkg thru
3,5 mkg (280 in lb thru 305 in lb) (only for LH install
the pipe clamp).
6.Connect electrical connector (29DEA) (13) to Low
Pressure Switch (12).
(Cont'd)
29-10-10