background image
TCH.1C-27J-2-29JG
2-16.1
REMOVAL (refer to figure 
2-14, sheet 1/5
) , (refer
to figure 
2-14, sheet 2/5
) , (refer to figure 
2-14,
sheet 3/5
) , (refer to figure 
2-14, sheet 4/5
) and
(refer to figure 
2-14, sheet 5/5
) (Cont'd)
WARNING
––––––––––––––––––––––––––––––––––
FOR REMOVAL USE THREE PERSONS
TO PREVENT INJURY.
––––––––––––––––––––––––––––––––––
CAUTION
––––––––––––––––––––––––––––––––––
Don't use drained fluid from hydraulic
system.
––––––––––––––––––––––––––––––––––
CAUTION
––––––––––––––––––––––––––––––––––
Use precaution when you remove the
engine driven pump to prevent damage
to driven shaft.
––––––––––––––––––––––––––––––––––
1.Close the HYDRAULICS SOV ENG 1 (61DE) (1)
(HYDRAULICS SOV ENG 2 (34DE) (2)) circuit
breaker, located on the overhead circuit breakers
panel (271VE) in position B 1 (B 2).
(Cont'd)
29-10-15
2-100