TCH.1C-27J-2-29JG
2-17.1
figure
B.HYD ACMP 1 (2DE) (15) located in position R 8;
C.115 VAC BUS 1 OFF (63XA) (18) located in
position T 5;
D.115 VAC BUS 2 OFF (64XA) (17) located in
position T 9.
3.Ensure that the following circuit breakers located on
Overhead Circuit Breakers Panel (271VE) are closed:
A.HYDRAULICS CNTR ACMP 2 (3DE) (12) located
in position B 8;
B.HYDRAULICS CNTR ACMP 1 (4DE) (9) located in
position B 7;
C.HYDRAULICS LOW PREE CHNL 1 (18DE) (13)
located in position B 9;
D.HYDRAULICS LOW PRESS CHNL 2 (19DE) (14)
located in position B 10;
E.HYDRAULICS IND PRESS (31DE) (11) located in
position B 6;
F.HYDRAULICS IND QTY (33DE) (10) located in
position B 5.
4.Select to ACMP 1 (ACMP 2) switches (4 and 5) to ON
position.
5.Verify that the ACMP 1 (ACMP 2) starts to run.
6.Verify that the hydraulic triple pressure indicator (8)
pointer HYD SYS 1 (HYD SYS 2) located on central
main instrument panel shows 3000 psi - 0/+ 150 psi
(210 kg/cm
²
- 0/+ 10.5 kg/cm
²
).
7.On the Hydraulic/Smoke Detection Control Panel
(204VE) (1), verify that:
(Cont'd)
29-10-20
2-115