background image
TCH.1C-27J-2-29JG
2-22.1
REMOVAL (refer to figure 
2-20
) (Cont'd)
CAUTION
––––––––––––––––––––––––––––––––––
Do not use drained fluid from Hydraulic
System. A hydraulic fluid leak may occur.
This would cause damage to the
equipment and loss of mission
effectiveness.
––––––––––––––––––––––––––––––––––
1.Use a container to collect drained fluid.
CAUTION
––––––––––––––––––––––––––––––––––
Install protection caps on the
disconnected hoses.
––––––––––––––––––––––––––––––––––
2.Loosen nut of the outlet pipe (6) and disconnect it.
3.Loosen nut of the inlet pipe (1) and disconnect it.
4.Remove the relief valve (4) by removing bolts (2) and
washers (3).
5.Remove from relief valve (4), the unions (7 and 9) and
the preformed packings (5 and 8). Discard removed
preformed packing.
2-22.2
INSTALLATION (refer to figure 
2-20
)
NOTE
Remove protection caps from the hoses to
be installed.
1.Install at the relief valve (4), the unions (7 and 9) and
the new preformed packings (5 and 8) (LCM NO.
00027). Torque tighten (AGE NO. 00054) unions to
280 in lb thru 305 in lb (3.2 mKg thru 3.5 mKg).
2.Install the relief valve (4) by using bolts (2) and
washers (3). Torque tighten (AGE NO.00054) bolts to
29 in lb thru 33 in lb (0.3 mKg thru 0.4 mKg).
(Cont'd)
29-10-30
2-155