TCH.1C-27J-2-29JG
Consumable Material Required:
None
Safety Conditions:
maintenance.
PROCEDURE:
2-24.1
)
WARNING
––––––––––––––––––––––––––––––––––
YOU MUST RELEASE THE PRESSURE IN
THE SYSTEM BEFORE YOU DO THIS
PROCEDURE.
––––––––––––––––––––––––––––––––––
CAUTION
––––––––––––––––––––––––––––––––––
Do not use drained fluid from hydraulic
system.
––––––––––––––––––––––––––––––––––
1.Use a container to collect drained fluid.
2.Take note of the correct valve orientation (look for the
arrow indication located on the body of the valve).
3.Disconnect the clamps (1 and 5) by removing screws
(7 and 9) and washers (6 and 8).
CAUTION
––––––––––––––––––––––––––––––––––
Install the protection cups on the pipes
that you disconnect.
––––––––––––––––––––––––––––––––––
4.Loosen nuts and remove the pipes (2 and 4).
(Cont'd)
29-10-35
2-168