TCH.1C-27J-2-29JG
2-25.1
) (Cont'd)
CAUTION
––––––––––––––––––––––––––––––––––
Be careful when you disconnect the
outlet pipe nut. A gross hydraulic fluid
leakage may occur.
––––––––––––––––––––––––––––––––––
5.Loosen the outlet end of hydraulic line (6).
6.Remove the check valve (5) taking care not to flex the
pipe.
2-25.2
)
1.Install the check valve (5) by tighten the outlet pipe
nut. Verify correct valve orientation (look for thearrow
on the body of the valve. For RH side only in must be
directed upside down). Torque tighten to 143 in lb thru
215 in lb (1.6 mkg thru 2.4 mkg).
NOTE
Remove protection caps from the hoses to
be installed.
2.Install the inlet pipe (1). Tighten the nut on body filter
side and the inlet pipe nut on check valve (5) at 143 in
lb thru 215 in lb (1.6 mkg thru 2.4 mkg);
3.Fasten the retaining clamp (3) using screw (2) and
washer (3).
FOLLOW ON MAINTENANCE:
1.Connect external electrical power (refer to manual
2.Select the ACMP 2 switch to ON position.
29-10-35
2-175