TCH.1C-27J-2-29JG
-2 filters (2) on the delivery of No. 2 system pumps.
-1 filter (6) on the case drain line of No. 2 system
pumps (installed on reservoir No. 2).
2.The 5 micron filters are installed as follows (refer to
figure
) :
-1 filter (4) on the return line of No. 1 system
(installed on reservoir No. 1).
-1 filter (1) on the return line of No. 2 system
(installed on reservoir No. 2).
CAUTION
––––––––––––––––––––––––––––––––––
Do not clean filter elements with petrol or
other non approved methods.
Before fitting the filter element, immerse
it completely in clean hydraulic fluid.
––––––––––––––––––––––––––––––––––
3.Devices in the hydraulic system such as brake valves,
selector valves, rams etc. are supplied with small
protective filters. These filters are an integral part of
the device and must not be removed during ordinary
filter cleaning operations. Such operations should be
carried out at the overhaul center or in departments
suitably qualified and equipped for 2nd level
maintenance operations on those devices.
1-18