background image
TCH.1C-27J-2-29JG
Consumable Material Required:
LCM
No.
NOMENCLATURE
P/N
QTY
00016
LOCK WIRE
MS20995C32
AR
00043
HYDRAULIC FLUID
MIL-PRF-83282D
AR
Safety Conditions:
Be aware of information contained in SAFETY
PRECAUTIONS (refer to para 
1-8
) before performing
maintenance.
PROCEDURE:
2-5.1
Carry out sampling procedure as follows:
NOTE
Hydraulic fluid must be at ambient
temperature.
A.Open the access panel 414J (424J) and 414D
(424D) located in the LH (RH) nacelle.
B.Cut the lockwire of reservoir drain cock.
NOTE
It is possible to operate with the ACMP1
(ACMP2).
C.Connect the external electrical supply from the
aircraft.
D.Set up the hydraulic test stand as follows: delivery
pressure 3000 psi (210 kg/cm2).
NOTE
Use graduated container for discarded
hydraulic fluid.
E.By opening very slowly the reservoir drain cock,
drain and discard about 500 c.c. of hydraulic fluid.
F.Using a steril sampler take the necessary quantity
of fluid and send to laboratory.
(Cont'd)
29-10-00