2-29.2 INSTALLATION. Install the Rudder accumulator as
follows:
NOTE
Lubricate all packings and O-ring with
hydraulic fluid.
A.Install the Rudder accumulator.
B.Hold the accumulator, then screw the screws that
lock the clamps fixing the accumulator.
C.Place new O-rings on the inlet and outlet pipe and
connect it on the accumulator torque tightenthe nut
on top of inlet and outlet pipe.
D.Place new O-rings on the sensorial pipe and
connect it on the accumulator torque tighten the
nuton top of sensorial pipe.
E.Remove from the aircraft the container with
drained fluid.
CAUTION
––––––––––––––––––––––––––––––––––
Dont use the drained fluid collected to
refill hydraulic circuit because it is
contamined. Discard it.
––––––––––––––––––––––––––––––––––
F.Install the cover plate on the left fuselage side
ramp area.
FOLLOW ON MAINTENANCE:
1.Restore hydraulic power system (refer to manual
2.Connect electrical power to aircraft (refer to manual
3.Close thermal insulation screen.
4.Enable cargo ramp control.
5.Perform the functional test:
) .
27-20-25
2-245