TCH.1C-27J-2-27JG
2-43
OPERATIONAL TEST ELEVATOR MANUAL
MODE
INPUT CONDITION:
Aircraft Applicability:
04162, 04180
Required Conditions:
None
Recomended Personnel:
Not Provided
AGE Required:
None
Consumable Material Required:
None
Safety Conditions:
None
PROCEDURE:
A.Depressurize both hydraulic No. 1 and No. 2.
B.Perform from 2 to 4 complete manoeurves at least
by the pilot control stick in pitch direction (from
neutral to fully forward then to fully backwards and
returning to neutral) in order to discharge the
elevator system No. 2 accumulator.
C.Activate the reserve hydraulic accumulators by
pressing the accumulator pushbutton (FCS2
Control Panel) (lamp ON illuminated).
27-30-00
2-331