background image
TCH.1C-27J-2-27JG
2-50.2 CENTERING SPRING ADJUSTMENT (refer to
figure 
1-57, sheet 3/4
) and (refer to figure 
1-57,
sheet 4/4
) (Cont'd)
2.Disconnect centering spring (46) from LH (RH)
elevator actuator (41) by removing bolt (42), washer
(43), bushing (47), castellated nut (44) and cotter pin
(45). Discard removed cotter pin.
3.Remove the lock wire (48), then acting on the locking
nut (49), adjust the centering spring (46), so that the
fixing bolt enters freely on the LH (RH) elevator
actuator (41) (centering spring set to neutral position).
4.Tighten (AGE NO. 00054) the locking nut (49) and
lock it with new lock wire (48).
5.Verify the correct engagement of the threads end.
Check that no more than 3 threads are visible on each
terminal lug.
6.Connect centering spring (46) at the LH (RH) elevator
actuator (41) by using bolt (42), washer (43), bushing
(47), castellated nut (44) and new cotter pin (45) (LCM
NO. 00010).
7.Remove a 0.193 in (4.915 mm) (AGE NO. 00181) (37
and 39) diameter rigging pin from LH and RH rear
quadrants (38 and 40).
FOLLOW ON MAINTENANCE:
None
27-30-15
2-403