TCH.1C-27J-2-27JG
) (Cont'd)
4.Reconnect the bonding lead (7) using bolt (5) and
washer (6) then Torque tighten the bolt to 8 - 10 In lb
(AGE NO. 00054).
NOTE
Remove protection caps from the electrical
connectors to be installed.
5.Reconnect electrical connector (1) with Q-FEEL
Actuator (7CG) (4).
FOLLOW ON MAINTENANCE:
1.Close thermal insulation screen.
2.Enable Cargo Ramp Control.
3.Connect electrical power to aircraft (refer to manual
4.Restore hydraulic power system (refer to manual
5.Perform the functional test:
A.MANOEUVRE EFFORT AND Q-FEEL
FUNCTIONAL CHECK (refer to para
27-30-40