TCH.1C-27J-2-27JG
Safety Conditions:
Be aware of information contained in Paragraph (refer to
para
maintenance.
PROCEDURE:
2-68.1 REMOVAL. Remove elevator accumulator as
follows:
NOTE
Install the protection cap on the pipes and
the electrical connectors that you
disconnect.
WARNING
––––––––––––––––––––––––––––––––––
OPEN ALL THE NITROGEN CHARGING
VALVE VERY SLOWLY TO PREVENT
NITROGEN VAPOR FROM COMING IN
TOUCH WITH THE EYES. DO NOT
BREATHE THE NITROGEN VAPOR
COMING OUT FROM THE NITROGEN
CHARGING VALVE; IT COULD BE MIXED
WITH HYDRAULIC FLUID.
––––––––––––––––––––––––––––––––––
CAUTION
––––––––––––––––––––––––––––––––––
Seal all open pipes and component holes
to prevent entrance of unwanted material.
––––––––––––––––––––––––––––––––––
A.Remove the cover plate from the left (right)
fuselage side ramp area.
B.Use container to collect drained fluid.
27-30-70
2-508