background image
TCH.1C-27J-2-27JG
Table 2-9. Flap adjustment and specification
 Flap lever position
 Outer Flap Surface
Travel
 Nominal
Resistence-ohms
 Position % of applied
nominal voltage to the
transducer
UP
  0° - 1mm /  +7mm
 33.8
 6.76 %
1
 11.25°
 135.2
 27.04 %
2
 22.5°
 231
 46.02 %
3
 33.75°
 331
 66.02 %
 Full
 45°
 422
 84.40 %
Recomended Personnel:
PROCEDURE
MECH.
CODE QTY
TOTAL TIME
(MIN.)
WORK
ZONE
Test
AFM
1
150,00
Periodicity: AR - AS REQUIRED
Total Maintenance Time: 150 (Min.)
Total Time Detention System: 150 (Min.)
AGE Required:
AGE
No.
NOMENCLATURE
P/N
00034 Kit, dynamometers
A37781-000
00061 Kit, digital inclinometers
G0002700001
00067 Kit, flaps check templates
G0002750001
00181 Kit, flight controls rigging
pins
11G001-C052200-801
Consumable Material Required:
None
Safety Conditions:
Be aware of information contained in SAFETY
PRECAUTIONS (refer to para 
1-8
) before performing
maintenance.
27-50-10
2-540