TCH.1C-27J-2-27JG
Table 2-9. Flap adjustment and specification
Flap lever position
Outer Flap Surface
Travel
Nominal
Resistence-ohms
Position % of applied
nominal voltage to the
transducer
UP
0° - 1mm / +7mm
33.8
6.76 %
1
11.25°
135.2
27.04 %
2
22.5°
231
46.02 %
3
33.75°
331
66.02 %
Full
45°
422
84.40 %
Recomended Personnel:
PROCEDURE
MECH.
CODE QTY
TOTAL TIME
(MIN.)
WORK
ZONE
Test
AFM
1
150,00
Periodicity: AR - AS REQUIRED
Total Maintenance Time: 150 (Min.)
Total Time Detention System: 150 (Min.)
AGE Required:
AGE
No.
NOMENCLATURE
P/N
00034 Kit, dynamometers
A37781-000
00061 Kit, digital inclinometers
G0002700001
00067 Kit, flaps check templates
G0002750001
00181 Kit, flight controls rigging
pins
11G001-C052200-801
Consumable Material Required:
None
Safety Conditions:
Be aware of information contained in SAFETY
PRECAUTIONS (refer to para
maintenance.
27-50-10
2-540