background image
TCH.1C-27J-2-27JG
2-71.4 CHECK OF POSITION 3 (refer to figure 
1-86,
sheet 1/7
) and (refer to figure 
1-86, sheet 7/7
)
(Cont'd)
D.the position difference between left inboard and
right inboard and also between left outboard and
right outboard flaps surface must not be greater
than 1°.
2.Extend completely the flaps. Return the flap control
lever (4) to 3 position and check the following
conditions:
A.the outboard flaps retract to 33.75 ° ± 1° (read on
digital inclinometer).
B.the inboard flaps retract to 15
°
  ± 1 ° (read on
digital inclinometer).
C.the manoeuvre time (from FULL to 3) must be
between 4.5 and 5.5 sec;
3.Retract the flaps to UP.
4.Press the flaps selection pushbutton to illuminate
NORM legend.
2-71.5 CHECK OF FLAP TRAVEL AND CLEARANCE
(refer to figure 
1-86, sheet 1/7
) , (refer to figure
1-86, sheet 7/7
) , (refer to figure 
1-86, sheet 6/7
) ,
(refer to figure 
1-86, sheet 4/7
) and (refer to figure
1-86, sheet 5/7
)
1.On flap control panel, ensure that the flap control lever
(4) is to UP position and the flap surfaces are
retracted (0 position).
2.Fit flap templates (AGE NO. 00067) to LH and RH
outer wings.
(Cont'd)
27-50-10
2-543