TCH.1C-27J-2-27JG
2-74.1 CHECK OF FLAP POSITION INDICATOR (1)
(refer to figure
2.Move the flap control lever (2) to 1 position and check
that:
-the flap indicator position shows;
-the ACAWS caution FLAP ASYM is not displayed
on CMDU (3).
3.Move the flap control lever (2) to 2 position and check
that:
-the flap indicator position shows 2;
-the ACAWS caution FLAP ASYM is not displayed
on CMDU (3).
4.Move the flap control lever (2) to 3 position and check
that:
-the flap indicator position shows 3;
-the ACAWS caution FLAP ASYM is not displayed
on CMDU (3).
5.Move the flap control lever (2) to FULL position and
check that:
-the flap indicator position shows FULL;
-the ACAWS caution FLAP ASYM is not displayed
on CMDU (3).
6.Return the flaps to UP position.
FOLLOW ON MAINTENANCE:
None
27-50-20
2-572