TCH.1C-27J-2-27JG
Consumable Material Required:
LCM
No.
NOMENCLATURE
P/N
QTY
00010 PIN, COTTER
MS24665-155
2,00
00013 NUT, SELF-LOCKING H14-4
6,00
00014 NUT, SELF-LOCKING MS21042L08
4,00
00036 PIN, COTTER
MS24665-154
1,00
00052 PIN, COTTER
MS24665-153
1,00
00433 AEROSHELL 17
MIL-G-21164D
AR
00434 AEROSHELL
33MS077009
MIL-G-21164D
AR
Safety Conditions:
Be aware of information contained in SAFETY
PRECAUTIONS (refer to para
maintenance.
PROCEDURE:
2-75.1 REMOVAL (refer to figure
) , (refer
to figure
NOTE
Position a container in order to collect
drained hydraulic liquid
1.Remove the bungee (6) from the FDCU lever (5) by
removing the cotter pin (2), bolt (12), washers (4 and
13) and nut (3). Discard removed the cotter pin.
2.Remove the bungee (1) from the flap quadrant lever
(7) by removing the cotter pin (11), bolt (8), washer (9)
and nut (10). Discard removed the cotter pin.
3.Remove clamp (22) connecting pipe (23) to the
bracket (43) and clamps (14, 15 and 21) between
pipes (23, 24 and 25).
(Cont'd)
27-50-25
2-575