background image
TCH.1C-27J-2-27JG
3.Set to zero the counter contained in the Kit Flap
rigging, rotate counter clockwise the Flap Arrester Unit
rotating shaft (corresponding to flap extension) up to
the intervention of the Flap Arrester Unit stop
mechanism. Check by means of counter, that the
numbers of shaft revolution is 155 รท 158 .
4.Rotate clockwise 3 turns the Flap Arrester Unit shaft.
FOLLOW ON MAINTENANCE:
None
27-50-35
2-594