TCH.1C-27J-2-27JG
Consumable Material Required:
LCM
No.
NOMENCLATURE
P/N
QTY
00052 PIN, COTTER
MS24665-153
2,00
Safety Conditions:
Be aware of information contained in SAFETY
PRECAUTIONS (refer to para
maintenance.
PROCEDURE:
2-83.1 REMOVAL (refer to figure
) , (refer
to figure
) and (refer to figure
1.Insert rigging pin (8) (AGE NO. 00181) into the cable
sector (12).
2.Gain access through opened access panels,
disconnect preselection rod (bungee) (5) from flap
hydraulic actuator control lever (1) by removing bolt
(7), washers (6 and 4), castellated nut (2) and cotter
pin (3). Discard removed cotter pin.
3.Remove bolt (13), washer (11), castellated nut (10)
and cotter pin (9) connecting preselection rod
(bungee) (5) to the cable sector (12). Discard
removed cotter pin.
4.Remove preselection rod (bungee) (5).
2-83.2 INSTALLATION (refer to figure
(refer to figure
)
1.On the flap position indicator panel (14) switch to
NORMAL.
2.Ensure that flap input lever (16), located on the FCS 1
Control Panel (103 VE) (15), is to up position.
(Cont'd)
27-50-55