TCH.1C-27J-2-27JG
2-93
LIFT DUMPER CONTROL SYSTEM - OTHER
CHECK SPECIAL ALERTS
INPUT CONDITION:
Aircraft Applicability:
04162, 04180
Required Conditions:
None
Recomended Personnel:
PROCEDURE
MECH.
CODE QTY
TOTAL TIME
(MIN.)
WORK
ZONE
Test
ELT
1
30,00
Periodicity: AR - AS REQUIRED
Total Maintenance Time: 30 (Min.)
Total Time Detention System: 30 (Min.)
AGE Required:
None
Consumable Material Required:
None
Safety Conditions:
Be aware of information contained in SAFETY
PRECAUTIONS (refer to para
maintenance.
PROCEDURE:
2-93.1 CHECK OF SPECIAL ALERT (refer to figure
)
1.Annul the hydraulic pressure in both systems.
2.Set-up the following conditions:
(Cont'd)
27-60-05
2-671