TCH.1C-27J-2-27JG
Safety Conditions:
Be aware of information contained in SAFETY
PRECAUTIONS (refer to para
maintenance.
PROCEDURE:
)
CAUTION
––––––––––––––––––––––––––––––––––
Install protection caps on the
disconnected hoses.
––––––––––––––––––––––––––––––––––
1.Use a container in order to collect drained hydraulic
fluid.
2.Gain access through the opened access panels.
3.Loosen the nuts and disconnect the pipes (2, 3, 4, 6,
and 8) from the FCU restrictor valves (1, 5, and 7).
4.Remove FCU restrictor valves (1, 5, and 7).
5.Discard removed preformed packing.
CAUTION
––––––––––––––––––––––––––––––––––
Take care to respect position of the
valve.
––––––––––––––––––––––––––––––––––
CAUTION
––––––––––––––––––––––––––––––––––
Don't use the drained hydraulic fluid
collected to refill hydraulic circuit. It is
contamined discard it.
––––––––––––––––––––––––––––––––––
(Cont'd)
27-60-15
2-693