2-98.2 INSTALLATION. The installation procedure of the
control valve is the following: (Cont'd)
E.Connect inlet pipe to actuator and torque tighten
the nut.
F.Remove plug from return pipe.
G.Connect return hydraulic pipe and torque tighten
the nut.
H.Remove plug from pipe.
I.Connect supply hydraulic pipe torque tighten the
nut.
J.Connect electric connector.
K.Remove the container used for collect drained
fluid.
CAUTION
––––––––––––––––––––––––––––––––––
Dont use the drained fluid collected to
refill the hydraulic circuit because it is
contamined. Discard it.
––––––––––––––––––––––––––––––––––
FOLLOW ON MAINTENANCE:
1.Close the access panels 913H, 913I, 913B, 913A and
621N.
2.Restore hydraulic power system (refer to manual
3.Connect electrical power to aircraft (refer to manual
4.Perform the functional test LIFT DUMPER CONTROL
SYSTEM (refer to para
).
27-60-25
2-705