background image
TCH.1C-27J-2-27JG
Consumable Material Required:
LCM
No.
NOMENCLATURE
P/N
QTY
00022 PIN, COTTER
MS24665-86
2,00
Safety Conditions:
Be aware of information contained in SAFETY
PRECAUTIONS (refer to para 
1-3
) before performing
maintenance.
PROCEDURE:
2-100.1 REMOVAL (refer to figure 
1-119, sheet 1/2
) and
(refer to figure 
1-119, sheet 2/2
)
WARNING
––––––––––––––––––––––––––––––––––
PERSONNEL AND EQUIPMENT SHALL
REMAIN CLEAR OF CARGO RAMP AND
DOOR AREA WHENEVER THE
AUXILIARY HYDRAULIC SYSTEM IS
PRESSURIZED. FAILURE TO COMPLY
COULD INJURY PERSONNEL OR
DAMAGE EQUIPMENT.
––––––––––––––––––––––––––––––––––
1.Remove the clips (1 and 4), then acting on the
turnbuckles (2 and 3), slowly release the cable
tension.
2.Disconnect the cable end (22) from bellcrank assy
(21) at frame 42 by removing bolt (23), washer (20),
castellated nut (19) and cotter pin (18). Discard
removed cotter pin.
3.Loosen the cable end (22) from the cable (5).
4.Disconnect the cable end (15) from elevator locking
lever assembly (10) by removing bolt (9), washer (11),
castellated nut (13) and cotter pin (12). Discard
removed cotter pin.
(Cont'd)
27-70-05
2-717