TCH.1C-27J-2-29JG
2-7
BLEEDING HYDRAULIC SYSTEM - BLEED
INPUT CONDITION:
Aircraft Applicability:
04162, 04180
Required Conditions:
NOTE
To ensure the best results, the following
rules should be observed whenever a
hydraulic component is refitted.
1.To avoid a large volume of air entering the system, fill
the component concerned with hydraulic fluid before
fitting.
2.Before reconnecting the coupling, bleed the section of
piping upstream the disconnected component using
the hand pump hydraulic stand (AGE NO. 00264).
3.All hydraulic actuators removed should be refilled with
fluid and bled before being refitted.
4.Check the test stand reservoir (AGE NO. 00262) and
top up if necessary to the correct level. The test stand
reservoir must be at least 3/4 full.
5.After having carried out a bleeding operation,
pressurize with hand pump hydraulic stand (AGE NO.
00264) before starting up engine.
6.Open the access panels 913A and 913B.
Recomended Personnel:
PROCEDURE
MECH.
CODE
QTY
TOTAL TIME
(MIN.)
WORK
ZONE
Input Condition
AFM
2
6,00
Test
AFM
2
26,00
Follow
Maintenance
AFM
2
6,00
29-10-00
2-45