TCH.1C-27J-2-29JG
1.Use a container to collect drained fluid.
2.Loosen the nut and disconnect the return hydraulic
pipe (3).
3.Remove union (4) and preformed packing (3). Discard
removed preformed packing.
4.Cut the lock wire (7).
5.Disconnect the return filter (1) by removing the two
screws (2).
6.Remove the nipple from the return filter (1).
7.Remove and discard two packing from return filter (1).
)
NOTE
Remove protection caps from the hoses to
be installed.
1.Loosen the filter bowl (6).
2.Install two new packings into the groove of the nipple.
3.Carefully, insert the nipple into the return filter (1).
4.Install the return filter (1) using two screws (2).
5.Install the new lock wire (7).
6.Torque tighten both screws (2) to 22 in lb (0.255 m kg)
thru 31 in lb (0.357 m kg) (AGE NO. 00054).
7.Connect union (4) and new preformed packing (3)
(LCM NO. 00027) to return filter (1).
8.Connect the return hydraulic pipe (5) and tighten the
nut.
9.Fill filter bowl (6) with clean hydraulic fluid (LCM NO.
00043).
10.Torque tighten the filter bowl (6) to 354 in lb thru 443
in lb (4.1 m kg thru 5.1 m kg) (AGE NO. 00054).
29-10-05
2-80