background image
TCH.1C-27J-2-29JG
2-14.2 INSTALLATION (refer to figure 
2-11
) (Cont'd)
7.Loosen filter bowl and check presence of filter
element. If not present install a new filter element
(refer to para 
2-15
) .
8.Fill filter bowl with clean (class 5) hydraulic fluid.
9.Torque tighten the filter bowl to 4,1 mkg thru 5,1 mkg
(354 in lb thru 443 in lb).
10.Connect the hand pump hydraulic stand (AGE NO.
00264) to ACMP1 (ACMP2) delivery quick
disconnection.
CAUTION
––––––––––––––––––––––––––––––––––
Avoid hydraulic fluid spilling using a
clean cloth. This will prevent damage to
the equipment due to corrosion.
––––––––––––––––––––––––––––––––––
11.Operate the hand pump hydraulic stand (AGE NO.
00264) and check that the hydraulic fluid flowing from
the filter inlet pipe nut (8) is free from bubbles.
12.Torque tighten (AGE NO. 00054) the inlet pipe nut (8)
to 143 in lb thru 215 in lb (1.6 mKg thru 2.4 mKg).
CAUTION
––––––––––––––––––––––––––––––––––
Avoid hydraulic fluid spilling using a
clean cloth. This will prevent damage to
the equipment due to corrosion.
––––––––––––––––––––––––––––––––––
13.Operate the hand pump hydraulic stand (AGE NO.
00264) and check that the hydraulic fluid flowing from
the filter tee reducer pipe (1) downstream nut is free
from bubbles.
14.Torque tighten (AGE NO. 00054) the tee reducer pipe
(1) downstream nut to 143 in lb thru 215 in lb (1.6
mKg thru 2.4 mKg).
(Cont'd)
29-10-10
2-99