background image
TCH.1C-27J-2-29JG
2-15.1 REMOVAL (refer to figure 
2-12
) (Cont'd)
CAUTION
––––––––––––––––––––––––––––––––––
Do not use drained fluid from Hydraulic
System. A hydraulic fluid leak may occur.
This would cause damage to the
equipment and loss of mission
effectiveness.
––––––––––––––––––––––––––––––––––
1.Cut lock wire (2).
2.Loosen filter bowl (1).
3.Remove filter element.
2-15.2 INSTALLATION (refer to figure 
2-12
)
1.Install a new filter element into filter bowl (1).
2.Fill filter bowl with clean hydraulic fluid (LCM NO.
00043).
3.Torque tighten (AGE NO. 00054) the filter bowl to 354
in lb thru 443 in lb (4.1 mKg thru 5.1 mKg).
4.Install lock wire (2).
FOLLOW ON MAINTENANCE:
1.Close the access panels 913A and 913B (923A and
923B).
2.Connect external electrical power (refer to manual
TCH.1C-27J-2-00GV
) .
29-10-10
2-104