TCH.1C-27J-2-29JG
2-21.1 REMOVAL (refer to figure
) , (refer
to figure
)
(Cont'd)
6.Loosen the nuts of the outlet pipe (10) that connects
the two TEE reducer (16 and 19) and remove the
pipe.
7.Loosen the nut of the pressure transducer pipe (18)
on TEE reducer side (19).
8.Hold the accumulator (12) and loose the clamps (23).
9.Remove the accumulator (12) and its two clamps (23)
from the support.
10.Collect the two metallic clamps (23).
11.Remove union reducer (14) of hydraulic fluid inlet side
and discard packing (13).
12.Remove TEE union reducer nut (20). Collect nut (20)
and discard retainer (22) and packing (21).
13.Remove union (9) on nitrogen side of accumulator
and discard packing (10).
2-21.2 INSTALLATION (refer to figure
(refer to figure
) , (refer to figure
) and (refer to figure
)
NOTE
Lubricate all packings and performed
packings with hydraulic fluid
NOTE
Remove protection caps from the hoses to
be installed.
1.Install the new packing (LCM NO. 00031) (10) on the
union (9), install the union (9) on the nitrogen inlet port
of the accumulator (12) and torque tighten (AGE NO.
00054) to 1,1 mkg thru 1,2 mkg (95 in lb thru 105 in
lb).
(Cont'd)
29-10-25