background image
TCH.1C-27J-2-29JG
Consumable Material Required:
LCM
No.
NOMENCLATURE
P/N
QTY
00026 RETAINER,
PACKING
MS28773-08
1,00
00027 PACKING,
PREFORMED
M83461/2-908
2,00
00031 PACKING,
PREFORMED
M83461/2-904
1,00
00073 PACKING,
RETAINER
MS28773-04
1,00
Safety Conditions:
Be aware of information contained in SAFETY
PRECAUTIONS (refer to para 
1-7
) before performing
maintenance.
PROCEDURE:
2-22.1 REMOVAL (refer to figure 
2-19, sheet 1/3
) and
(refer to figure 
2-19, sheet 2/3
)
WARNING
––––––––––––––––––––––––––––––––––
BEFORE YOU REMOVE THE LINE
ACCUMULATOR, RELEASE THE
PRESSURE IN THE SYSTEM AND
DISCHARGE THE NITROGEN FROM THE
ACCUMULATORS. THIS WILL HELP TO
PREVENT INJURIES TO PERSONNEL
AND DAMAGE TO THE EQUIPMENT.
––––––––––––––––––––––––––––––––––
(Cont'd)
29-10-25
2-156