TCH.1C-27J-2-29JG
) (Cont'd)
WARNING
––––––––––––––––––––––––––––––––––
HYDRAULIC FLUID IS ACID. AVOID
CONCTACT WITH SKIN AND WEAR
APPROPRIATE, IMPERVIOUS CLOTHING
WHEN HANDLING THE HYDRAULIC
FLUIDS. IF YOU DO NOT OBEY THESE
SAFETY PRECAUTIONS, SEVERE
INJURY MAY OCCUR.
––––––––––––––––––––––––––––––––––
CAUTION
––––––––––––––––––––––––––––––––––
Do not use drained fluid from Hydraulic
System. A hydraulic fluid leak may occur.
This would cause damage to the
equipment and loss of mission
effectiveness.
––––––––––––––––––––––––––––––––––
CAUTION
––––––––––––––––––––––––––––––––––
Install protection caps on the
disconnected electrical connectors and
hoses.
––––––––––––––––––––––––––––––––––
1.Use a container to collect drained fluid.
2.Disconnect electrical connector (26DEA) (7) from low
pressure switch (12).
NOTE
For the right side disconnect the electrical
connector (27DEA).
3.Remove clamp (11) by removing bolt (10), washer (8)
and nut (6) from support.
(Cont'd)
29-10-35
2-173