background image
TCH.1C-27J-2-29JG
Consumable Material Required:
None
Safety Conditions:
Be aware of information contained in SAFETY
PRECAUTIONS (refer to para 
1-8
) before performing
maintenance.
PROCEDURE:
2-26.1 REMOVAL (refer to figure 
2-23
)
WARNING
––––––––––––––––––––––––––––––––––
YOU MUST RELEASE THE PRESSURE IN
THE SYSTEM BEFORE YOU DO THIS
PROCEDURE.
––––––––––––––––––––––––––––––––––
CAUTION
––––––––––––––––––––––––––––––––––
Do not use drained fluid from hydraulic
system.
––––––––––––––––––––––––––––––––––
1.Use a container to collect drained fluid.
2.Take note of the correct valve orientation (look for the
arrow indication located on the body of the valve).
3.Loosen the check valve clamp (4) and collect washer
(3) and screw (2).
CAUTION
––––––––––––––––––––––––––––––––––
Install protection caps on the
disconnected hoses.
––––––––––––––––––––––––––––––––––
4.Loosen the nuts of inlet hydraulic line pipe (1) on
check valve (5) and on bulkhead union, remove the
pipe (1).
(Cont'd)
29-10-35
2-186