TCH.1C-27J-2-29JG
PROCEDURE:
NOTE
Aim of the test described in this paragraph is
to verify the correct electro-hydraulic
functionality of the Hydraulic System.
NOTE
This procedure is valid for left nacelle. For
right nacelle is similar.
2-27.1 FUNCTIONAL TEST OF FIRE SHUT-OFF
VALVES - FUNCTIONAL TEST (refer to figure
)
and (refer to figure
WARNING
––––––––––––––––––––––––––––––––––
TO PREVENT INJURY TO PERSONEL DO
NOT ROTATE THE FIRE HANDLE. ONLY
PULL OUT THE FIRE HANDLE.
––––––––––––––––––––––––––––––––––
WARNING
––––––––––––––––––––––––––––––––––
OPEN THE CIRCUIT BREAKERS FIRE
ENGINES EXTG 1 (1WE) (3) AND FIRE
ENGINES EXTG 2 (2WE) (4) LOCATED ON
OVERHEAD CIRCUIT BREAKERS PANEL
(271VE) IN POSITIONS D 21 AND D 23
AND THE CIRCUIT BREAKERS FIRE
EXTG ENG 1 (3WE) (7) AND FIRE EXTG
ENG 2 (4WE) (8) LOCATED ON REAR MID
CIRCUIT BREAKERS PANEL (451VE) IN
POSITIONS K 11 AND K 12.
––––––––––––––––––––––––––––––––––
(Cont'd)
29-10-40
2-191